SHAKE SPECIFICATIONS

SIZE OF COVER:1265mm (L) X 368mm (W) / 50″ X 14.5″
ACCESSORIES:Refer to flashing specifications
PROTECTIVE COATING:*Zincalume (*Reg. Trademark of BIEC Intl. Inc)
SUBSTRATE:G300
MECHANICAL PROPERTIES:Grade 33
BASE METAL THICKNESS:0.39mm
COATING WEIGHT:AZ-150 Zincalume
PRIMER:2 Micron acrylic pigmented colour coating
MINIMUM PITCH:15 degrees
WEIGHT:2.0kg per panel or 4.40kg per sam (Textured Specs)
PALLET SIZE:1110mm (W) x 1405mm (L) x 97mm (H) – Contains 400 pallets
EXPOSED FASTENED BATTENS:Tiles are installed from top of roof down to fascia. Standard install four (4) fasteners per panel through the front down turned nose.
HVNZ:High Velocity Hurricane Zone areas require special fasteners and in a specific pattern.
Refer to Tilcor HVNZ install details for more information.

ROYAL SPECIFICATIONS

SIZE OF COVER:1260mm (L) X 368mm (W) / 50″ X 14.5″
ACCESSORIES:Refer to flashing specifications
PROTECTIVE COATING:*Zincalume (*Reg. Trademark of BIEC Intl. Inc)
SUBSTRATE:G300
MECHANICAL PROPERTIES:Grade 33
BASE METAL THICKNESS:0.39mm
COATING WEIGHT:AZ-150 Zincalume
PRIMER:2 Micron acrylic pigmented colour coating
MINIMUM PITCH:15 degrees
WEIGHT:2.9kg per panel or 6.30kg per sqm
PALLET SIZE:1110mm (W) x 1405mm (L) x 97mm (H) – Contains 400 pallets
EXPOSED FASTENED BATTENS:Tiles are installed from top of roof down to fascia. Standard install of four (4) fasteners per panel through the front down turned nose.
HVNZ:High Velocity Hurricane Zone areas require special fasteners and in a specific pattern.
Refer to Tilcor HVNZ install details for more information.

TUDOR SPECIFICATIONS

SIZE OF COVER:1265mm (L) X 368mm (W) / 50″ X 14.5″
ACCESSORIES:Refer to flashing specifications
PROTECTIVE COATING:*Zincalume (*Reg. Trademark of BIEC Intl. Inc)
SUBSTRATE:G300
MECHANICAL PROPERTIES:Grade 33
BASE METAL THICKNESS:0.39mm
COATING WEIGHT:AZ-150 Zincalume
PRIMER:2 Micron acrylic pigmented colour coating
MINIMUM PITCH:12.5 degrees
WEIGHT:2.0kg per panel or 4.40kg per sqm (Textured Specs)
PALLET SIZE:1110mm (W) x 1405mm (L) x 97mm (H) – Contains 400 pallets
EXPOSED FASTENED BATTENS:Tiles are installed from top of roof down to fascia. Standard install of four (4) fasteners per panel through the front down turned nose.
HVNZ:High Velocity Hurricane Zone areas require special fasteners and in a specific pattern.
Refer to Tilcor HVNZ install details for more information.

SHINGLE SPECIFICATIONS

SIZE OF COVER:1250mm (L) X 250mm (W) / 49″ X 10″
ACCESSORIES:Refer to flashing specifications
PROTECTIVE COATING:*Zincalume (*Reg. Trademark of BIEC Intl. Inc)
SUBSTRATE:G300
MECHANICAL PROPERTIES:Grade 33
BASE METAL THICKNESS:0.39mm
COATING WEIGHT:AZ-150 Zincalume
PRIMER:2 Micron acrylic pigmented colour coating
MINIMUM PITCH:20.0 degrees
WEIGHT:2.0kg per panel or 4.40kg per sqm
PALLET SIZE:1110mm (W) x 1405mm (L) x 97mm (H) – Contains 400 pallets
EXPOSED FASTENED BATTENS:Tiles are installed from top of roof down to fascia. Standard install of four (4) fasteners per panel through the front down turned nose.
HVNZ:High Velocity Hurricane Zone areas require special fasteners and in a specific pattern.
Refer to Tilcor HVNZ install details for more information.

ROMAN SPECIFICATIONS

SIZE OF COVER:1220mm (L) X 368mm (W) / 48″ X 14.5″
ACCESSORIES:Refer to flashing specifications
PROTECTIVE COATING:*Zincalume (*Reg. Trademark of BIEC Intl. Inc)
SUBSTRATE:G300
MECHANICAL PROPERTIES:Grade 33
BASE METAL THICKNESS:0.39mm
COATING WEIGHT:AZ-150 Zincalume
PRIMER:2 Micron acrylic pigmented colour coating
MINIMUM PITCH:12.5 degrees
WEIGHT:2.0kg per panel or 4.40kg per sqm
PALLET SIZE:1110mm (W) x 1405mm (L) x 97mm (H) – Contains 400 pallets
EXPOSED FASTENED BATTENS:Tiles are installed from top of roof down to fascia. Standard install of four (4) fasteners per panel through the front down turned nose.
HVNZ:High Velocity Hurricane Zone areas require special fasteners and in a specific pattern.
Refer to Tilcor HVNZ install details for more information.

CLASSIC SPECIFICATIONS

SIZE OF COVER:1265mm (L) X 368mm (W) / 50″ X 14.5″
ACCESSORIES:Refer to flashing specifications
PROTECTIVE COATING:*Zincalume (*Reg. Trademark of BIEC Intl. Inc)
SUBSTRATE:G300
MECHANICAL PROPERTIES:Grade 33
BASE METAL THICKNESS:0.39mm
COATING WEIGHT:AZ-150 Zincalume
PRIMER:2 Micron acrylic pigmented colour coating
MINIMUM PITCH:12.5 degrees
WEIGHT:2.0kg per panel or 4.40kg per sqm
PALLET SIZE:1110mm (W) x 1405mm (L) x 97mm (H) – Contains 400 pallets
EXPOSED FASTENED BATTENS:Tiles are installed from top of roof down to fascia. Standard install of four (4) fasteners per panel through the front down turned nose.
HVNZ:High Velocity Hurricane Zone areas require special fasteners and in a specific pattern.
Refer to Tilcor HVNZ install details for more information.

BOND SPECIFICATIONS

SIZE OF COVER:1265mm (L) X 368mm (W) / 50″ X 14.5″
ACCESSORIES:Refer to flashing specifications
PROTECTIVE COATING:*Zincalume (*Reg. Trademark of BIEC Intl. Inc)
SUBSTRATE:G300
MECHANICAL PROPERTIES:Grade 33
BASE METAL THICKNESS:0.39mm
COATING WEIGHT:AZ-150 Zincalume
PRIMER:2 Micron acrylic pigmented colour coating
MINIMUM PITCH:12.5 degrees
WEIGHT:2.0kg per panel or 4.40kg per sqm
PALLET SIZE:1110mm (W) x 1405mm (L) x 97mm (H) – Contains 400 pallets
EXPOSED FASTENED BATTENS:Tiles are installed from top of roof down to fascia. Standard install of four (4) fasteners per panel through the front down turned nose.
HVNZ:High Velocity Hurricane Zone areas require special fasteners and in a specific pattern.